ver : c_2 update : 2012.05.03 ac-dc switching power supply aqf360e series 360 watts http://www.archcorp.com.tw tel: +886-2-26989508 fax: +886-2-26981319 -1- electrical specifications model no. aqf360e-12s aqf360e-24s aq f360e-36s aqf360e-48s AQF360E-54S max output wattage (w) 360w voltage 90-264 vac or 120-370 vdc frequency (hz) 47-63 hz current (full load) < 4.0 a max. (115 vac) / < 2.0 a max. (230 vac) inrush current (<2ms) < 30 a max. (115 vac) / < 60 a max. (230 vac) leakage current < 0.3 ma max.(240vac 63hz) input power factor pf>0.98 (115 vac) / pf>0.93 (230 vac) at full load voltage (v.dc.) 12v 24v 36v 48v 54v trim 10.8 ~ 13.2v 21.6 ~ 26.4v 32.7 ~ 39.6v 44 ~ 51v 51.3 ~ 56.7v voltage accuracy 2% current (convection) (a) max 30 15 10 7.5 6.66 line regulation (ll-hl) (typ.) 1% loa d regulation (5-100%) (typ.) 1% minimum load 1% maximum capacitive load 85000 uf 48000 uf 21000 uf 13000 uf 7000 uf ripple & noise (max.) 150mvp-p 200mvp-p efficiency (typ.) 89% 91% 92% 93% 93% hold-up time 12 ms min. output switching frequency 75 khz over power protection auto recovery over voltage protection auto recovery over temperature auto recovery protection short circuit protection auto-recovery input-output (v.ac) 3000v input-fg (v.ac) 1500v isolation output-fg . (v.ac) 500v operating temperature -10c?+70c (with derating) storage temperature -25c?+85c temperature coefficient 0.03%/c ( 0~50c ) humidity 95% rh mtbf >120,000 h @ 25c (mil-hdbk-217f) environment vibration 10~500hz, 2g 10min./1cycle, 60min. each along x, y, z axes. key features ? enclosed switching power supply ? universal input: 90-264 vac ? with p.f.c. function, pf>0.95 ? cooling by built-in 12 vdc fan ? 240w convection without fan ? protections: over load / over voltage / over temperature / short circuit . all by auto-recovery ? leakage current <300ua ? high power density ? high efficiency up to 93% ? rohs compliant design ? ultra compact size: 6.8 x 3.2 x 2.1 inches ? 3-years product warranty standard a type 1. all specifications valid at normal input voltage, full load and +25c after warm-up time unless otherwise stated. 2. ripple & noise are measured a t 20mhz of bandwidth with 0.1uf & 47uf parallel capacitor.
ver : c_2 update : 2012.05.03 ac-dc switching power supply aqf360e series 360 watts http://www.archcorp.com.tw tel: +886-2-26989508 fax: +886-2-26981319 -2- electrical specifications model no. aqf360e-12s aqf360e-24s aq f360e-36s aqf360e-48s AQF360E-54S dimension (l x w x h) 6.8 x 3.2 x 2.1 inches (172.7 x 81.3 x 53.3 mm ) tolerance 0.5 mm weight 729 g physical cooling method cooling by built-in dc fan safety agency approvals ce, ul60950 emi (conducted & radiated emission) en 55022 class b emc ems (noise immunity) en 55024 mechanical dimension ( top view ) standard pin# single 1 fg 2 ac in (n) 3 ac in (l) 4~6 +dc out 7~9 -dc out a type pin# single 1 fg 2 ac in (n) 3 ac in (l) 4~9 +dc out 10~15 -dc out 1. all specifications valid at normal input voltage, full load and +25c after warm-up time unless otherwise stated. 2. ripple & noise are measured a t 20mhz of bandwidth with 0.1uf & 47uf parallel capacitor.
ver : c_2 update : 2012.05.03 ac-dc switching power supply aqf360e series 360 watts http://www.archcorp.com.tw tel: +886-2-26989508 fax: +886-2-26981319 -3- block diagram derating assembly instructions *u case t=2.0mm customer screws into the length of the case no higher than 0.5mm (namely screw length for load plate thickness plus 2.5mm
ver : c_2 update : 2012.05.03 ac-dc switching power supply aqf360e series 360 watts http://www.archcorp.com.tw tel: +886-2-26989508 fax: +886-2-26981319 -4- efficiency versus load aqf360e-12s vin vs efficiency load vs efficiency input voltage (v) 90 115 180 230 264 efficiency (%) 86.12 88.20 90.15 90.69 90.95 load (%) 0 10 20 30 40 50 115v (%) 0 83.25 87.43 89.02 89.67 89.80 230v (%) 0 84.38 88.94 90.75 91.24 91.49 load (%) 60 70 80 90 100 115v (%) 89.64 89.39 89.00 88.65 88.20 230v (%) 91.46 91.38 91.22 91.02 90.09 75.00% 77.50% 80.00% 82.50% 85.00% 87.50% 90.00% 92.50% 95.00% 90v 115v 180v 230v 264v vin eff% 0.00% 10.00% 20.00% 30.00% 40.00% 50.00% 60.00% 70.00% 80.00% 90.00% 100.00% 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% load eff% aqf360e-24s vin vs efficiency load vs efficiency input voltage (v) 90 115 180 230 264 efficiency (%) 88.36 90.35 92.13 92.67 92.96 load (%) 0 10 20 30 40 50 115v (%) 0 84.77 88.62 90.54 91.14 91.33 230v (%) 0 85.54 90.08 92.06 92.62 92.99 load (%) 60 70 80 90 100 115v (%) 91.32 91.18 90.98 90.70 90.35 230v (%) 93.08 93.08 93.02 92.91 92.67 75.00% 77.50% 80.00% 82.50% 85.00% 87.50% 90.00% 92.50% 95.00% 90v 115v 180v 230v 264v vin eff% 0.00% 10.00% 20.00% 30.00% 40.00% 50.00% 60.00% 70.00% 80.00% 90.00% 100.00% 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% load eff%
ver : c_2 update : 2012.05.03 ac-dc switching power supply aqf360e series 360 watts http://www.archcorp.com.tw tel: +886-2-26989508 fax: +886-2-26981319 -5- efficiency versus load aqf360e-36s vin vs efficiency load vs efficiency input voltage (v) 90 115 180 230 264 efficiency (%) 89.04 91.17 93.06 93.64 93.93 load (%) 0 10 20 30 40 50 115v (%) 0 80.96 86.76 89.39 90.51 91.01 230v (%) 0 85.51 90.25 92.24 92.82 93.39 load (%) 60 70 80 90 100 115v (%) 91.21 91.36 91.37 91.31 91.17 230v (%) 93.46 93.68 93.76 93.68 93.64 75.00% 77.50% 80.00% 82.50% 85.00% 87.50% 90.00% 92.50% 95.00% 90v 115v 180v 230v 264v vin eff% 0.00% 10.00% 20.00% 30.00% 40.00% 50.00% 60.00% 70.00% 80.00% 90.00% 100.00% 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% load eff% aqf360e-48s vin vs efficiency load vs efficiency input voltage (v) 90 115 180 230 264 efficiency (%) 89.75 91.89 93.79 94.36 94.67 load (%) 0 10 20 30 40 50 115v (%) 0 86.43 89.33 9143 92.17 92.58 230v (%) 0 8680 90.87 92.74 93.47 94.02 load (%) 60 70 80 90 100 115v (%) 92.58 93.00 92.38 92.18 91.89 230v (%) 94.02 94.23 94.24 94.40 94.36 75.00% 77.50% 80.00% 82.50% 85.00% 87.50% 90.00% 92.50% 95.00% 90v 115v 180v 230v 264v vin eff% 0.00% 10.00% 20.00% 30.00% 40.00% 50.00% 60.00% 70.00% 80.00% 90.00% 100.00% 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% load eff%
ver : c_2 update : 2012.05.03 ac-dc switching power supply aqf360e series 360 watts http://www.archcorp.com.tw tel: +886-2-26989508 fax: +886-2-26981319 -6- efficiency versus load AQF360E-54S vin vs efficiency load vs efficiency input voltage (v) 90 115 180 230 264 efficiency (%) 88.12 90.58 92.65 93.79 93.99 load (%) 0 10 20 30 40 50 115v (%) 0.00 86.37 88.87 89.82 90.28 90.91 230v (%) 0.00 88.59 91.67 92.80 93.35 93.66 load (%) 60 70 80 90 100 115v (%) 90.98 90.96 90.95 90.87 90.58 230v (%) 93.79 93.83 93.86 93.80 93.79 75.00% 77.50% 80.00% 82.50% 85.00% 87.50% 90.00% 92.50% 95.00% 90v 115v180v230v264v vin eff% 0.00% 10.00% 20.00% 30.00% 40.00% 50.00% 60.00% 70.00% 80.00% 90.00% 100.00% 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% load eff%
|